The hybrid method for the plate-finned tube evaporator design process

نویسندگان

چکیده

The plate-finned tube evaporator performance, in terms of heat transfer rate and refrigerant pressure drops, is influenced by several choices done during the design process to be carried out complying with different constraints. In this paper circuitry layout options together other parameters variations were investigated purpose supporting designers. Performance predictions calculated using hybrid method as well appropriate Evaluation Criteria (PEC) adopted select best layout. has been here revised improved aiming at modelling exchangers an approach closer real configurations that include complex circuit layouts. was chosen its main advantage (high accuracy results low computational costs) allowed easily perform operating conditions modifications compared.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a finned-tube evaporator optimized for different refrigerants and its effect on system efficiency

This paper presents a comparable evaluation of R600a (isobutane), R290 (propane), R134a, R22, R410A, and R32 in an optimized finned-tube evaporator, and analyzes the impact of evaporator effects on the system coefficient of performance (COP). The study relied on a detailed evaporator model derived from NIST’s EVAP-COND simulation package and used the ISHED1 scheme employing a non-Darwinian lear...

متن کامل

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

An experimental investigation was implemented to determine the capacity degradation due to non-uniform refrigerant and air flow distributions, and to assess the potential to recover the lost capacity via controlling refrigerant distribution between individual refrigerant circuits. The tests were performed on a three-circuit, threedepth-row, finned-tube evaporator. Refrigerant inlet quality, exi...

متن کامل

Effect of Coil Geometry on Frost-Free Finned-Tube Evaporator Performance

This paper outlines a mathematical modelling approach to predict the steady-state behaviour of finned-coil evaporators. The model was built taking three domains into account: (i) refrigerant flow inside the coil; (ii) heat transfer through the walls; and (iii) air flow through the finned-coil array. The equations were obtained from the mass, momentum and energy conservation principles, mathemat...

متن کامل

Heat and Mass Transfer Coefficients Under Frost Conditions In A Finned-Tube Evaporator

The objectives of this study are to provide experimental data and a correlation that can be used in the optimal design of an evaporator under frost conditions. In the present study, we tested both a single stage and a two-stage evaporator with a variation of operating parameters and fin geometry under frost conditions. The effects of tube space and fin alignment on the heat transfer performance...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2021

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202131203004