Numerical study of fluid flow and heat transfer in a gas-tank water heater

Influence of a vent hood at the exit of exhaust flue gas and flue baffles in the firetube on the temperature and flow fields of a gas tank water heater, as well as thestructure and amount of heat transferred to the water tank has been studiednumerically using two-dimensional steady state finite element simulation.Observations show that without a vent hood, there is a downward gas flow in theflu...

متن کامل

numerical study of fluid flow and heat transfer in a gas-tank water heater

influence of a vent hood at the exit of exhaust flue gas and flue baffles in the firetube on the temperature and flow fields of a gas tank water heater, as well as thestructure and amount of heat transferred to the water tank has been studiednumerically using two-dimensional steady state finite element simulation.observations show that without a vent hood, there is a downward gas flow in theflu...

متن کامل

Experimental Analysis of Solar Water Heater Using Pulsating Heat Pipe

Solar energy is used for solar water heater in domestic and industrial purpose. Pulsating heat pipe is a fast responding, flexible and high performance thermal conducting device. The CLPHP system described in this study relies on the natural forces of gravity and capillary action and does not require an external power source. The flat plate collector consisted of a 2 mm thick sheet of Aluminum ...

متن کامل

Fluid flow and heat transfer characteristics in a curved rectangular duct using Al2O3-water nanofluid

In the present research, the laminar forced convective heat transfer and fluid flow characteristics for Al2O3-water nanofluid flowing in different bend (i.e., 180o and 90o) pipes have been investigated numerically in a three-dimensional computational domain using the finite volume technique. The effects of different pertinent parameters, such as the Reynolds number of the duct, volume fraction ...

متن کامل

Experimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater

The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the charac...