The Effects of Magnetic Casson Blood Flow in an Inclined Multi-stenosed Artery by using Caputo-Fabrizio Fractional Derivatives

نویسندگان

چکیده

This paper investigates the magnetic blood flow in an inclined multi-stenosed artery under influence of a uniformly distributed field and oscillating pressure gradient. The is modelled using non-Newtonian Casson fluid model. governing fractional differential equations are expressed by Caputo-Fabrizio derivative without singular kernel. Exact analytical solutions obtained Laplace finite Hankel transforms for both velocities. velocities particles graphically presented. It shows that velocity increases with respect to Reynolds number parameter. Meanwhile, decreases as Hartmann increases. These results useful diagnosis treatment certain medical problems.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Electro-osmotic Slip Flow of an Oldroyd-B Fluid with Time-fractional Caputo-Fabrizio Derivative

In this article, the electro-osmotic flow of Oldroyd-B fluid in a circular micro-channel with slip boundary condition is considered. The corresponding fractional system is represented by using a newly defined time-fractional Caputo-Fabrizio derivative without singular kernel. Closed form solutions for the velocity field are acquired by means of Laplace and finite Hankel transforms. Additionally...

متن کامل

Optimality conditions for fractional variational problems with Caputo-Fabrizio fractional derivatives

*Correspondence: [email protected] Department of Mathematics, School of Science, Xi’an University of Posts and Telecommunications, Chang’an Road, Xi’an, China Abstract In this paper, we study the necessary and sufficient optimality conditions for problems of the fractional calculus of variations with a Lagrange function depending on a Caputo-Fabrizio fractional derivative. The new kernel of Capu...

متن کامل

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Blood flow is modeled as non-Newtonian micropolar fluid. The non-linear governing equations of continuum and momentum in the cylindrical coordinate are being discretized using a finite difference approach and have been solved iteratively ,through Crank-Nicolson method. The blood velocity distribution, volumetric flow rate and Resistance to blood flow at the stenosis throat are computed for vari...

متن کامل

the effects of changing roughness on the flow structure in the bends

flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...

Pulsatile MHD Flow in an Inclined Catheterized Stenosed Artery with Slip on the Wall

Catheter is commonly used by the surgeons for various reasons in the treatment of a patient suffering with cardiovascular diseases. Catheterization increases the mean flow resistance in the arterial blood flow and many other complications are associated with the presence of catheter in the artery. Effects of catheter in stenosed artery can be estimated non-invasively by means of hemodynamic ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Advanced Research in Fluid Mechanics and Thermal Sciences

سال: 2021

ISSN: ['2289-7879']

DOI: https://doi.org/10.37934/arfmts.82.2.2838