The Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V

Purpose It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect ...

متن کامل

Size threshold perimetry performs as well as conventional automated perimetry with stimulus sizes III, V, and VI for glaucomatous loss.

PURPOSE It is thought that large perimetric stimuli are insensitive for demonstrating visual field defects. To test the hypothesis that there is no difference in the total number of abnormal test locations with total deviation empiric probability plots in glaucoma patients, we compared results of glaucoma patients tested with sizes III (0.43° diameter), V (1.72°), and VI (3.44°), and size thres...

متن کامل

Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.

PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...

متن کامل

Quantification of glaucomatous visual field defects with automated perimetry.

A method to quantify different glaucomatous visual field defects is presented. Three visual field indices are calculated: the short-term fluctuation, the mean defect, and the corrected loss variation. The method was applied to visual fields tested with program JO on the Octopus automated perimeter. The indices of 130 glaucoma suspects and 50 glaucoma patients were compared with 100 normal contr...

متن کامل

Glaucomatous visual field progression with frequency-doubling technology and standard automated perimetry in a longitudinal prospective study.

PURPOSE To compare frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) for detecting glaucomatous visual field progression in a longitudinal prospective study. METHODS One eye of patients with open-angle glaucoma was tested every 6 months with both FDT and SAP. A minimum of 6 examinations with each perimetric technique was required for inclusion. Visual field...