The Discrimination of Inrush Current from Internal Fault of Power Transformer based on EMD
نویسندگان
چکیده
منابع مشابه
Different Methods of Differentiating Inrush Current from Internal Fault Current in Transformer
When a transformer is energized the phenomenon of magnetizing inrush current occurs and causes a pseudo tripping signal to the differential relay which leads to the problem of mal operation or false tripping of the relay. In order to avoid this false tripping of the differential relay and for safe operation of the transformer the distinction of inrush current with internal fault current is very...
متن کاملa novel approach for discrimination magnetizing inrush current and internal fault in power transformers based on neural network
one of the major problems that may occur in the differential protection systems of power transformers is mal-operation of the protection relays in sake of internal fault detection, because of similarity between this current and inrush current. this paper presents a novel approach for discriminating inrush current from internal fault in power transformers based on improved gravitational search a...
متن کاملSupport Vector Machine for Discrimination Between Fault and Magnetizing Inrush Current in Power Transformer
This study presents a novel technique based on Support Vector Machine (SVM) for the classification of transient phenomena in power transformer. The SVM is a powerful method for statistical classification of data. The input data to this SVM for training comprises fault current and magnetizing inrush current. SVM classifier produces significant accuracy for classification of transient phenomena i...
متن کاملDiscrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method
The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...
متن کاملPower Transformer Modeling for Inrush Current Calculation
The paper documents a new transformer model in ATPDraw called XFMR. This model handles 3-phase transformers with two or three windings. Autotransformers and all Wye and Delta couplings are supported. The model includes an inverse inductance matrix for the leakage description, optional frequency dependent winding resistance, capacitive coupling, and a topologically correct core model (3and 5-leg...