The direct X-ray detection with a charge coupled device.
نویسندگان
چکیده
منابع مشابه
A fast, direct x-ray detection charge-coupled device.
A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 microm thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output po...
متن کاملCharge-coupled device area x-ray detectors
Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...
متن کاملCalibration procedures for charge-coupled device x-ray detectors
Calibration procedures are described for use with electronic x-ray detectors, with an emphasis on detectors based on fiber-optically coupled charge-coupled devices. Methods are detailed for removing spurious events, pixel pedestals, dark-current, spatial distortion, and intensity response variations for both small-angle and wide-angle applications. The accuracy of the calibration procedures is ...
متن کاملArea x-ray detector based on a lens-coupled charge-coupled device
An area x-ray detector constructed using commercially available “off-the-shelf” parts is described and its performance is characterized. The detector consists of a 1024 1024 pixel charge-coupled device CCD camera optically coupled to x-ray sensitive phosphor screen using a standard 35 mm camera lens. The conversion efficiency, spatial nonuniformity, spatial resolution and the detective quantum ...
متن کاملDevelopment of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments.
This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10(14) photon/mm(2). The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Review of Laser Engineering
سال: 1990
ISSN: 0387-0200,1349-6603
DOI: 10.2184/lsj.18.11_923