The design of X-band EPR cavity with narrow detection aperture for in vivo fingernail dosimetry after accidental exposure to ionizing radiation
نویسندگان
چکیده
منابع مشابه
New Developed Cylindrical TM010 Mode EPR Cavity for X-Band In Vivo Tooth Dosimetry
EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concent...
متن کاملHuman EPR Dosimetry at Low Accumulated Dose of Ionizing Radiation Human EPR Dosimetry at Low Accumulated Dose of Ionizing Radiation
A new method for tooth (enamel and dentine) and bone EPR dosimetry is proposed that enhances substantially the dosimetric sensitivity. The method is based on the nonstandard spectra registration mode (the second harmonic phase quadrature detection of absorption under rapid passage conditions). This method provides an apparent enhancement of the component ratio of radiation to a nonradiative bac...
متن کاملAnalysis of Chromosome Aberrations in Human Lymphocytes after Accidental Exposure to Ionizing Radiation
Aim: Analysis of the results of cytogenetic examination and reconstruction of irradiation doses by the frequency of chromosome aberrations in the liquidators of the consequences of the Chernobyl NPP accident. Materials and methods: Over 1500 people who worked in the zone of the accident predominantly in 1986 and in 1987 have been examined since 1986. All of them were examined by means of the cl...
متن کاملNanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation
Giant magnetoresistive (GMR) nanosensors provide a novel approach for measuring protein concentrations in blood for medical diagnosis. Using an in vivo mouse radiation model, we developed protocols for measuring Flt3 ligand (Flt3lg) and serum amyloid A1 (Saa1) in small amounts of blood collected during the first week after X-ray exposures of sham, 0.1, 1, 2, 3, or 6 Gy. Flt3lg concentrations sh...
متن کاملBiological Dosimetry of Ionizing Radiation
A worsening of the accidental hazards linked to the use of ionizing radiation is currently being observed for four reasons. First, the increasing need for radiation sources in numerous industrial applications (food sterilization, construction, engineering...) leads to an increasing probability of loss of the sources or abnormal/unsuitable use and storage. Second, advances in medicine generate n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2021
ISSN: 2045-2322
DOI: 10.1038/s41598-021-82462-3