The DELPHI silicon strip microvertex detector with double sided readout
نویسندگان
چکیده
منابع مشابه
The OPAL Silicon Strip Microvertex Detector with Two Coordinate Readout
The OPAL experiment at the CERN LEP collider recently upgraded its silicon strip microvertex detector from one coordinate readout ( only) to two coordinate readout ( and z). This allows three dimensional vertex reconstruction and should improve lifetime measurements as well as b quark jet identi cation. This paper describes the new microvertex detector system with emphasis on the novel techniqu...
متن کاملCMOS Readout System for a Double-sided Germanium Strip Detector
A wide variety of applications require a hard Xray or gamma ray detector which combine both good spatial resolution and energy resolution. Double-sided solid-state strip detectors provide this capability. We report on the development of CMOS electronics designed for photon detection with strip detectors. These electronics include a low noise preamplifier, semi-gaussian shaping amplifier, discri...
متن کاملBeam Test of the SDC Double-sided Silicon Strip Detector
A beam test was executed to evaluate the behavior of the first prototype radiation-hard double-sided silicon microstrip sensor for the SDC silicon tracking system. Pions of 4 GeV/c in a test beamline at KEK illuminated three planes of detectors. The signals were amplified, shaped, and discriminated with TEKZ bipolar analog LSI's, and the on-off levels were sampled at 10MHz clock with CMOS digit...
متن کاملSiliSPECT: A Double-Sided Strip Silicon Detector-Based SPECT System
This work describes preliminary test studies with a dual-headed SPECT system that utilizes a new generation of silicon double-sided strip detectors (DSSDs) (Figure 1) with a 1-mm bulk thickness and larger active area (60 × 60 mm) as compared to standard gamma-ray silicon detectors. Furthermore, major improvements in the ASIC design make this detector very suitable for low-energy imaging of smal...
متن کاملCharacterization of a double-sided silicon strip detector autoradiography system.
PURPOSE The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1996
ISSN: 0168-9002
DOI: 10.1016/0168-9002(95)00699-0