The comparison analysis of earthquake resistant behavior between frame structure and frame shear wall structure
نویسندگان
چکیده
منابع مشابه
Investigation and Analysis of Empirical Field Seismic Damage to Bottom Frame Seismic Wall Masonry Structure
To understand the seismic damage characteristics of bottom frame-wall buildings and to study their seismic performance, the seismic damage outcomes of bottom frame-wall structures in Du jiang weir by the Wen chuan earthquake on May 12,2008, China were field observed and studied. The assesment of the seismic damage to the bottom frame-wall masonry in Du jiang weir urban showed that the damage t...
متن کاملinvestigation of frame and shear wall interaction
the combination of flexural frame and shear wall is one of the suitable systems to apply in reinforced concrete buildings. the deflections of flexural frame become limited due to the high stiffness of wall and the interaction of these systems. tall buildings even higher than fifty stories can be designed by using frame- wall systems. with respect to special behavior of flexural frame or shear w...
متن کاملthe underlying structure of language proficiency and the proficiency level
هدف از انجام این تخقیق بررسی رابطه احتمالی بین سطح مهارت زبان خارجی (foreign language proficiency) و ساختار مهارت زبان خارجی بود. تعداد 314 زبان آموز مونث و مذکر که عمدتا دانشجویان رشته های زبان انگلیسی در سطوح کارشناسی و کارشناسی ارشد بودند در این تحقیق شرکت کردند. از لحاظ سطح مهارت زبان خارجی شرکت کنندگان بسیار با هم متفاوت بودند، (75 نفر سطح پیشرفته، 113 نفر سطح متوسط، 126 سطح مقدماتی). کلا ...
15 صفحه اولShear Wall and Frame Interaction Terminology
Shear wall is one of the most commonly used lateral load resisting in high rise building. Shear wall has high in plane stiffness and strength which can be used to simultaneously resist large horizontal load and support gravity load. The objective of the present study is to study the behavior of building frame in the lateral load analysis of shear wall-frame structures; a fundamental goal is to ...
متن کاملAnalysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Earth and Environmental Science
سال: 2021
ISSN: 1755-1315
DOI: 10.1088/1755-1315/669/1/012014