منابع مشابه
THE NORMAL CARRYING ANGLE OF THE ELBOW IN SHIRAZ
The normal carrying angle in Shiraz population was measured on the basis of sex and age. The right elbow angle of 4266 cases was examined from birth to 30 years old. This study found the carrying angle in 2540 females to be 7.20 (range 2-19) and in 1726 males to be 6.40 (range 2-11), a 0.80 difference. A significant difference (p= 0.05) was found in relation to age. There is a gradual incr...
متن کاملthe normal carrying angle of the elbow in shiraz
the normal carrying angle in shiraz population was measured on the basis of sex and age. the right elbow angle of 4266 cases was examined from birth to 30 years old. this study found the carrying angle in 2540 females to be 7.20 (range 2-19) and in 1726 males to be 6.40 (range 2-11), a 0.80 difference. a significant difference (p= 0.05) was found in relation to age. there is a gradual increase ...
متن کاملStudy Of Carrying Angle And Its Correlation With Various Parameters
The role of carrying angle in the sex determination and its cause of formation is a long debated issue in Anatomy and Anthropology. Most studies have focused on the question of cause of formation of carrying angle, difference in sex and age but little attention has been given to correlate the carrying angle with various parameters. Hence, an effort has been made to find out correlation of carry...
متن کاملComparative Study of Carrying Angle in South Indian Population
Address for Correspondence: K.Praveen, Assistant Professor, Department of Anatomy, Al-Azhar Medical College and Super Specialty Hospitals, Thodupuzha, Kerala, India. E-Mail: [email protected] Introduction: Carrying angle (CA) is the acute angle made by the median axis of the arm with that of the fully extended and supinated forearm. Studies conducted to compare the differences between radio...
متن کاملDosimetric Effect Resulting From the Collimator Angle, the Isocenter Move, and the Gantry Angle Errors
Introduction: Dose distribution can be affected by diverse parameters, such as beam orientations, and collimator angles. These parameters should respect and maintain the international recommended levels during the realization of the quality assurance protocols of linear accelerators. This study aimed at evaluating the dosimetric effects on treatment quality considering...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Anatomical Record
سال: 1916
ISSN: 0003-276X,1097-0185
DOI: 10.1002/ar.1090100607