The Behaviour of Fasteners under External Loading : Force Ratio of Threaded Connections
نویسندگان
چکیده
منابع مشابه
Fatigue of Threaded Fasteners
ADVANCED MATERIALS & PROCESSES • AUGUST 2014 18 F asteners play a critical role in engineered structures as a method of nonpermanent joining for the aerospace, infrastructure, civil, automotive, energy generation/distribution, and many other industries. Fastener failures can lead to disastrous consequences and substantial financial losses. One of the most common fastener failure modes is fatigu...
متن کاملMathematical Modeling of Column-Base Connections under Monotonic Loading
Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base...
متن کاملStability of Manipulator Configuration under External Loading
The paper is devoted to the analysis of robotic manipulator behavior under internal and external loadings. The main contributions are in the area of stability analysis of manipulator configurations corresponding to the loaded static equilibrium. In contrast to other works, in addition to usually studied the end-platform behavior with respect to the disturbance forces, the problem of configurati...
متن کاملAnalytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملmathematical modeling of column-base connections under monotonic loading
some considerable damage to steel structures during the hyogo-ken nanbu earthquake occurred. among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. the lessons from these phenomena led to the need for improved understanding of column base...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of JSME
سال: 1986
ISSN: 0021-3764,1881-1426
DOI: 10.1299/jsme1958.29.617