The Behavior of Masonry Walls with Reinforced Plaster Mortar
نویسندگان
چکیده
منابع مشابه
Effect of Mortar Type on the Seismic Response of Partially Grouted Reinforced Masonry Shear Walls
Since the establishment of ASTM standard C91, masonry cement mortars have become widely used for masonry construction in low to moderate seismic regions. However, the Masonry Standards Joint Committee Code prohibits the use of masonry cement mortars in lateral force resisting systems for structures that fall into Seismic Design Categories D, E, and F. The general objective of this study is to e...
متن کاملRetrofit of Un-Reinforced Infill Masonry Walls with FRP
This paper describes an experimental program that deals with retrofitting of infill un-reinforced masonry walls (URM) with Fiber Reinforced Polymer (FRP). The primary objective of this research is to develop a retrofit strategy that while economical will minimize the influence of the retrofit on the overall performance of structural frames in predominant seismic regions. Allowing some damage to...
متن کاملeffects of fiber reinforced plaster on the earthquake behavior of masonry buildings
in this paper the traditional covering plaster of masonry buildings is supplied with polypropylene and steel fiber to enhance their seismic behavior. the plaster mix proportion is determined by some initial mortar tests. also, one story, single span masonry building specimen plastered with different mortars is tested on a shaking table 8 times under a seismic input and the performance of the sp...
متن کاملPractical Nonlinear Analysis for Limit Design of Reinforced Masonry Walls
Two modeling techniques for practical nonlinear static analysis are implemented to support the development and usage of a new Limit Design method for special reinforced masonry shear walls. The new seismic design alternative is under consideration for future versions of the building code requirements for masonry structures in the U.S. The proposed simplified models were applied to a planar one-...
متن کاملSeismic Performance of Reinforced Concrete Frames Infilled by Masonry Walls with Different Heights
This study carried out comparative seismic performance of reinforced concrete frames infilled by masonry walls with different heights. Partial and fully infilled reinforced concrete frames were modeled for the research objectives and the analysis model for a bare reinforced concrete frame was also established for comparison. Non–linear static analyses for the studied frames were performed to in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Materials Science and Engineering
سال: 2013
ISSN: 1687-8434,1687-8442
DOI: 10.1155/2013/436946