The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementing PFC Average Current Mode Control using the MC9S12E128

This application note is intended as an addendum to the Design Reference Manual DRM064 ([1]) and describes implementation of an average current mode control of Power Factor Correction (PFC) on MC9S12E128. The DRM064 deals with the design of a Single Phase On-Line UPS using an MC9S12E128. It includes control of a power factor correction (PFC), a DC/DC step up converter, a battery charger, and an...

متن کامل

Analog low-voltage current-mode implementation of digital logic gates

In this letter a new technique is introduced for implementing the basic logic functions using analog current‐mode techniques. By expanding the logic functions in power series expressions, and using summers and multipliers, realization of the basic logic functions is simplified. Since no transistors are working in saturation, the problem of fan‐out is alleviated. To illustrate the proposed techn...

متن کامل

Digital Current Mode Control for Buck-Converter Based on Average Inductor Current Measurement

This paper introduces a digitally performed current mode and voltage control for the dc-dc step down converter based on voltage to frequency converter where the average values of inductor current and output voltage are obtained. These current and voltage measurement are realized by the voltage control oscillator (VCO) and counters (digital integrator). Such an approach enables full digitalizati...

متن کامل

Average Current Mode Control of Switching Power Supplies

Current mode control as usually implemented in switching power supplies actually senses and controls peak inductor current. This gives rise to many serious problems, including poor noise immunity, a need for slope compensation, and peak-to-average current errors which the inherently low current loop gain cannot correct. Average current mode control eliminates these problems and may be used effe...

متن کامل

A directional-based branches current method for transmission loss allocation in the pool-based electricity market

This paper proposes a new method for transmission loss allocation. The share of each bus in the transmission line losses is determined using transmission line loss equations with respect to bus-injected currents. Then, it is applied to the total network transmission lines. In the proposed method, comparing with other methods, a solution to remove the negative loss allocation has been introd...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Transactions of the Korean Institute of Power Electronics

سال: 2014

ISSN: 1229-2214

DOI: 10.6113/tkpe.2014.19.2.133