Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience

American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation therapy (IGRT). The recommendations of AAPM TG 142 on IGRT are timely. In our institute, we established a comprehensive imaging QA program on a...

متن کامل

Feasibility study of performing IGRT system daily QA using a commercial QA device

The purpose of this study was to investigate the feasibility of using a single QA device for comprehensive, efficient daily QA of a linear accelerator (Linac) and three image-guided stereotactic positioning systems (IGSPSs). The Sun Nuclear Daily QA 3 (DQA3) device was used to perform daily dosimetry and mechanical accuracy tests for an Elekta Linac, as well as daily image geometric and isocent...

متن کامل

Erythrocyte survival is controlled by microRNA-142

Hematopoietic-specific microRNA-142 is a critical regulator of various blood cell lineages, but its role in erythrocytes is unexplored. Herein, we characterize the impact of microRNA-142 on erythrocyte physiology and molecular cell biology, using a mouse loss-of-function allele. We report that microRNA-142 is required for maintaining the typical erythrocyte biconcave shape and structural resili...

متن کامل

Early Liberal Fluid Therapy for Sepsis Patients Is Not Harmful: Hydrophobia Is Unwarranted but Drink Responsibly

Critical Care Medicine www.ccmjournal.org 2263 EARLY INTERVENTIONS IMPROVE OUTCOME Sepsis in the year 2016 remains the most expensive disease treated in hospitals and is the most common cause of in-hospital deaths in the United States (1). However, over the last 15 years, since the introduction of early goal-directed therapy (EGDT) and the Surviving Sepsis Campaign (SSC), there has been a consi...

متن کامل

UAIC Romanian QA System for QA@CLEF

This paper briefly describes UAIC’s participation in this year's CLEF question answering competition, focusing on the main challenges and changes compared to our last year participation. An analysis of the errors introduced by each module is also discussed.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Physics

سال: 2012

ISSN: 0094-2405

DOI: 10.1118/1.4766437