Testing of the cannon caliber rapid fire railgun
نویسندگان
چکیده
منابع مشابه
Design and Testing of a Rapid Fire, Lightweight, Ultra Stiff Railgun for a Cannon Caliber Electromagnetic Launcher System
The goal of the Cannon Caliber Program is to drive 185 g integrated launch packages to 1,850 d s . Three, fiveround salvos with a firing rate of 5 Hz are intended to defeat specified targets at a range of up to 3 km. After an extensive alternative study, the design team consisting of United Defence FMC/BMY, the Center for Electromechanics at The University of Texas at Austin (CEM-UT) and Kaman ...
متن کاملThe ER under rapid fire.
Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disease leading to selective death of upper and lower motoneurons. Clinically, the ALS syndrome is linked to pathogenic mutations in superoxide dismutase 1 (SOD1), though actual molecular mechanisms remain ill understood. Two papers recently published in Cell Stem Cell and Cell Reports employ syngenic, iPSC-derived cell lines of o...
متن کاملSystems Engineering a Naval Railgun
An effective systems engineering process will provide the framework to enable the complex technical endeavor of railgun system design and development to transition from a set of research projects to a viable acquisition program. The detailed formulation and application of the railgun systems engineering process will be defined by government acquisition agents and the selected private sector con...
متن کاملRapid Fire Hair Implanter Carousel
OBJECTIVE. To introduce a new surgical instrument, the Rapid Fire Hair Implanter Carousel (Carousel), which can automate the two most labor intensive parts of the hair transplantation process, site creation and implant placement, by combining them into a single step and delivering them in rapid sequence. This instrumentation should help to minimize some of the human factors contributing to graf...
متن کاملRapid-Fire Synaptic Vesicle Exocytosis
2ϩ-mediated regula-appears to be a requisite refractory period of at least tion of PIP 2 metabolism, Hardie et al. estimate that a 20 ms between fusion of one vesicle and the next at a single photon of light might deplete all of the PIP 2 in four single release site (Stevens and Wang, 1995), with a microvilli rather than the PIP 2 in the immediate vicinity of maximum rate of 15–30 fusion events...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Magnetics
سال: 1997
ISSN: 0018-9464
DOI: 10.1109/20.560084