Testing noncohesive geogrid-reinforced soil in triaxial shear apparatus under cyclic loading

نویسندگان

چکیده

In road base layers, geogrids assume the reinforcement or stabilization function where good interaction between geogrid and unbound material is important. The cyclic triaxial test can be used for analysing material. paper includes an overview of research primarily assessing influence parameters such as stiffness, geometry aperture size, position number on with layer to determine contribution application in non-cohesive materials has reduction permanent deformations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soil-Structure Interaction of Buried Pipes Under Cyclic Loading Conditions

The safety of lifelines, as the most important urban facilities, under different conditions highly depends on the safe design and performance of these buried structures. This cannot be achieved unless their actual behaviors are well understood and considered at the designing stage. A new physical model was developed in Amirkabir University of Technology to study the behavior of buried pipes und...

متن کامل

Behaviour of Reinforced Fibrous Concrete Beams under Reversed Cyclic Loading

When earthquakes occur, energy released by the earthquake gets induced into the structure as ground motion and this energy has to be dissipated for safety reasons. To release seismic energy, the structure should damage in such a way that on one hand, collapse of structure should not occur and on the other hand, after the earthquake, damage should be economically feasible to repair. To avoid the...

متن کامل

Shear and Flexural Stiffnesses of Reinforced Concrete Shear Walls Subjected to Cyclic Loading

Seismic analyses of concrete structures under maximum-considered earthquakes require the use of reduced stiffness accounting for cracks and degraded materials. Structural walls, different to other flexural dominated components, are sensitive to both shear and flexural stiffness degradations. Adoption of the gross shear stiffness for walls in seismic analysis prevails particularly for the design...

متن کامل

Experimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading

To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an &#10experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Gra?evinar

سال: 2021

ISSN: ['1849-1898', '1333-9095', '0350-2465']

DOI: https://doi.org/10.14256/jce.3039.2020