Testing Device for Biaxial Loading of Textile Specimens
نویسندگان
چکیده
منابع مشابه
The Design of Cruciform Test Specimens for Planar Biaxial Testing of Fabrics for Inflatable Aerodynamic Decelerators
A preliminary analytical study was conducted to investigate the effects of cruciform test specimen geometries on strain distribution uniformity in the central gage section under biaxial loads. Three distinct specimen geometries were considered while varying the applied displacements in the two orthogonal directions. Two sets of woven fabric material properties found in literature were used to q...
متن کاملA threshold loading device for testing of inspiratory muscle performance.
Threshold loading is a method of incrementally loading the inspiratory muscles, which requires development of an adjustable threshold pressure (Pth) before air will flow. In the ideal device, flow is independent of pressure once Pth is exceeded. A "weighted plunger" apparatus is commonly used, but devices described previously perform unreliably at high inspiratory load. We have modified this ap...
متن کاملRedesigning axial-axial (biaxial) cruciform specimens for very high cycle fatigue ultrasonic testing machines
The necessity to increase performances in terms of lifetime and security in mechanical components or structures is the motivation for intense research in fatigue. Applications range from aeronautics to medical devices. With the development of new materials, there is no longer a fatigue limit in the classical sense, where it was accepted that the fatigue limit is the stress level such that there...
متن کاملPrediction of Crack Initiation Direction for Inclined Crack Under Biaxial Loading by Finite Element Method
This paper presents a simple method based on strain energy density criterion to study the crack initiation angle by finite element method under biaxial loading condition. The crack surface relative displacement method is used to eliminate the calculation of the stress intensity factors which are normally required. The analysis is performed using higher order four node quadrilateral element. The...
متن کاملDesign of a biaxial mechanical loading bioreactor for tissue engineering.
We designed a loading device that is capable of applying uniaxial or biaxial mechanical strain to a tissue engineered biocomposites fabricated for transplantation. While the device primarily functions as a bioreactor that mimics the native mechanical strains, it is also outfitted with a load cell for providing force feedback or mechanical testing of the constructs. The device subjects engineere...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atlantis highlights in engineering
سال: 2023
ISSN: ['2589-4943']