Terbium Sensitized Determination of Tosufloxacin Using Electrochemiluminescence Method

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Terbium sensitized determination of tosufloxacin using electrochemiluminescence method.

A novel method for determination of trace amounts of tosufloxacin (TFLX) based on electrochemiluminescence (ECL) has been developed. The calibration graphs for TFLX were linear in the range of 5.0 x 10(-11)-3.5 x 10(-7) mol/L, with the detection limit of 1.3 x 10(-11) mol/L. Key factors affecting the determination of TFLX were investigated. TFLX amounts in capsule and serum samples were success...

متن کامل

Determination of norfloxacin using a terbium-sensitized electrogenerated chemiluminescence method.

A simple electrogenerated chemiluminescence (ECL) analysis method for the determination of norfloxacin (NFLX) is reported. It is based on ECL produced by Na(2)SO(3), which is sensitized by the Tb-NFLX complex. The relative ECL intensity of the Tb(3+)-NFLX-Na(2)SO(3) system is proportional to the amount of NFLX. The optimized experimental conditions were investigated. The linear range and detect...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Terbium Sensitized Chemiluminescence Method for the Determination of Rabeprazole -Application to Pharmaceutical Analysis and Dissolution Studies

A simple and sensitive chemiluminescence-based method was established for the determination of rabeprazole.The proposed method was based on the enhancing effect of rabeprazole on Ce(IV)-Na2SO3 -Tb(III) chemiluminescence reaction. A possible mechanism was discussed for chemiluminescence system by studying UV-Vis, fluorescence and chemiluminescence spectra. The effects of va...