Tension Band Wiring Technique for Distal Radius Fracture with a Volar Articular Marginal Fragment: Technical Note
نویسندگان
چکیده
منابع مشابه
Devising for a distal radius fracture fixation focus on the intra-articular volar dislocated fragment
INTRODUCTION Distal radius fracture (DRF) accompanied by intra-articular volar displaced fragment is difficult to reduce. This volar fragment remains when treated with a simple buttress effect alone, and V-shaped deformity may remain on the articular surface. We attempted to improve dorsal rotational deviation of volar fragment by osteosynthesis applying the condylar stabilizing technique. We r...
متن کاملModified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1
Background: Distal humeral fractures accounts for approximately 2% of all fractures and nearly one-third of humeralfractures in adults. In this regard, Modified Tension Bind Wiring (MTBW) technique was used for the fixation of the distalhumeral fractures type A2 and C1 (AO) to evaluate the early movement and complications of the patients.Methods: This study was conducted on 25...
متن کاملTension band wire for acetabular fracture fixation: a technical note.
Maintaining reduction of an acetabular fracture during internal fixation is difficult. A variety of clamps can be used to facilitate reduction, but they are cumbersome and may damage the sciatic nerve. We developed a simple and cost-effective technique for provisional reduction and fixation of acetabular fractures using 2 screws and a tension band wire.
متن کاملPercutaneous Tension-Band Suture Technique for Distal Patella Fracture Fixation
MOJ Orthop Rheumatol 2017, 8(3): 00315 reported rates up to 60 % [3,8,9]. For this reason, some have advocated the use of nonabsorbable sutures such as braided polyester, lowering the rate of revision surgery secondary to symptomatic hardware [3,10-14]. Studied suture material has included number 5 Ethibond (Ethicon, Somerville, NJ, USA), number 5 Ti-Cron (Davis and Geck, Gosport, Hampshire, UK...
متن کاملDistal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korean Fracture Society
سال: 2020
ISSN: 1225-1682,2287-9293
DOI: 10.12671/jkfs.2020.33.1.38