Tension Band Wire for Acetabular Fracture Fixation: A Technical Note
نویسندگان
چکیده
منابع مشابه
Tension band wire for acetabular fracture fixation: a technical note.
Maintaining reduction of an acetabular fracture during internal fixation is difficult. A variety of clamps can be used to facilitate reduction, but they are cumbersome and may damage the sciatic nerve. We developed a simple and cost-effective technique for provisional reduction and fixation of acetabular fractures using 2 screws and a tension band wire.
متن کاملUse of sutures as Kirschner wire and tension-band wire for olecranon fractures: a technical note.
Open reduction and internal fixation using tension-band wires for displaced olecranon fractures enables restoration of extensor function. We report on 3 elderly patients with a displaced olecranon fracture who underwent open reduction and internal fixation using sutures as the Kirschner wire and tension-band wire and achieved good outcome.
متن کاملArthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note
Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report...
متن کاملPercutaneous Tension-Band Suture Technique for Distal Patella Fracture Fixation
MOJ Orthop Rheumatol 2017, 8(3): 00315 reported rates up to 60 % [3,8,9]. For this reason, some have advocated the use of nonabsorbable sutures such as braided polyester, lowering the rate of revision surgery secondary to symptomatic hardware [3,10-14]. Studied suture material has included number 5 Ethibond (Ethicon, Somerville, NJ, USA), number 5 Ti-Cron (Davis and Geck, Gosport, Hampshire, UK...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Orthopaedic Surgery
سال: 2011
ISSN: 2309-4990,2309-4990
DOI: 10.1177/230949901101900328