Temperature feedback-controlled photothermal treatment with diffusing applicator: theoretical and experimental evaluations
نویسندگان
چکیده
منابع مشابه
Temperature feedback-controlled photothermal treatment with diffusing applicator: theoretical and experimental evaluations
To minimize thermal injury, the current study evaluated the real-time temperature monitoring with a proportional-integrative-derivative (PID) controller during 980-nm photothermal treatment with a radially-diffusing applicator. Both simulations and experiments demonstrated comparable thermal behaviors in temperature distribution and the degree of irreversible tissue denaturation. The PID-contro...
متن کاملSubjective Evaluations with Performance Feedback
This paper models two key roles of subjective performance evaluations: their incentive role and their feedback role. The paper shows that the feedback role makes subjective pay feasible even without repeated interaction, as long as there exists some veri able measure of performance. It also shows that while subjective pay is helpful, it cannot achieve full e¢ ciency. However, fully e¢ cient inc...
متن کاملTemperature-feedback upconversion nanocomposite for accurate photothermal therapy at facile temperature
Photothermal therapy (PTT) at present, following the temperature definition for conventional thermal therapy, usually keeps the temperature of lesions at 42-45 °C or even higher. Such high temperature kills cancer cells but also increases the damage of normal tissues near lesions through heat conduction and thus brings about more side effects and inhibits therapeutic accuracy. Here we use tempe...
متن کاملComparing experimental assessment of the peripheral dose outside the applicator in electron beams of ELEKTA with Treatment planning system
Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...
متن کاملA head and neck hyperthermia applicator: theoretical antenna array design.
PURPOSE Investigation into the feasibility of a circular array of dipole antennas to deposit RF-energy centrally in the neck as a function of: (1) patient positioning, (2) antenna ring radius, (3) number of antenna rings, (4) number of antennas per ring and (5) distance between antenna rings. MATERIALS AND METHODS Power absorption (PA) distributions in realistic, head and neck, anatomy models...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biomedical Optics Express
سال: 2016
ISSN: 2156-7085,2156-7085
DOI: 10.1364/boe.7.001932