Temperature Distribution and Cooling Rate of Welded Plates
نویسندگان
چکیده
منابع مشابه
Prediction of Weld Bead Parameters, Transient Temperature Distribution & Haz Width of Submerged Arc Welded Structural Steel Plates
Original scientific paper In a submerged arc welding process, the concept of temperature distribution is essential in order to control the HAZ (heat-affected zone) dimensions and get the required bead size and quality. In this paper, an analytical solution for moving heat source with Gaussian distribution of inside volume of central conicoidal shape is derived. Heat transfer in welded plates du...
متن کاملDistortion of laser welded titanium plates.
The distortion of laser welded titanium plates was assessed for different operating conditions of the laser welding device, and with different welding parameters (in terms of weld point and prewelding). In this study, Nd : YAG laser welding device was used to join the titanium plates. The results showed that distortion increased stepwise after each welding point along the welding zone (one-side...
متن کاملBending Response of Laser-welded Web-core Sandwich Plates
.............................................................................................................. 1 Tiivistelmä .......................................................................................................... 3 Preface ................................................................................................................ 5
متن کاملResidual stress evaluation in butt-welded steel plates
Faculty of Mechanical Engineering, Sardar Raja College of Engineering, Alangulam, Tirunelveli 627 808, India Faculty of Mechanical Engineering, Government College of Engineering, Tirunelveli 627 007, India Faculty of Mechanical Engineering, Alagappa Chettiar College of Engineering and Technology, Karaikudi 630 002, India Structural Analysis and Testing Group, Vikram Sarabhai Space Centre, Triva...
متن کاملHypercapnia increases core temperature cooling rate during snow burial.
Previous retrospective studies report a core body temperature cooling rate of 3 degrees C/h during avalanche burial. Hypercapnia occurs during avalanche burial secondary to rebreathing expired air, and the effect of hypercapnia on hypothermia during avalanche burial is unknown. The objective of this study was to determine the core temperature cooling rate during snow burial under normocapnic an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Japan Welding Society
سال: 1948
ISSN: 0021-4787,1883-7204
DOI: 10.2207/qjjws1943.17.9