Temperature correction method for dielectric response of high moisture content and aging degree oil impregnated paper based on segmented activation energy

نویسندگان

چکیده

Frequency Domain Spectroscopy (FDS) is widely used to estimate oil–paper insulation. The high moisture and long aging change the FDS characteristics of insulating oil–paper, so normalization processing required. Still, choice single activation energy needs further research. This paper studies characteristic insulation samples with different degrees improves traditional temperature correction method. enhanced Arrhenius model uses segmented make normalized curve coincide better target curve, error reduced. In addition, verify method’s effectiveness, this proposes an iterative process. It corrects tan δ-f bushing time 800 h based on energy, overall effect improved.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Method for Evaluating Moisture Content and Aging Degree of Transformer Oil-Paper Insulation Based on Frequency Domain Spectroscopy

The condition of oil-paper insulation is closely related to the life expectancy of a transformer. The accurate results of oil-paper have not been obtained due to the impact of influencing factors. Therefore, in order to improve the evaluation accuracy of oil-paper insulation, in this paper, oil-paper samples which were prepared with different aging and moisture content were analyzed by frequenc...

متن کامل

degradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses

در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...

15 صفحه اول

Study of the Impact of Initial Moisture Content in Oil Impregnated Insulation Paper on Thermal Aging Rate of Condenser Bushing

This paper studied the impact of moisture on the correlated characteristics of the condenser bushings oil-paper insulation system. The oil-impregnated paper samples underwent accelerated thermal aging at 130 ̋C after preparation at different initial moisture contents (1%, 3%, 5% and 7%). All the samples were extracted periodically for the measurement of the moisture content, the degree of polym...

متن کامل

Investigating the impacts of ageing and moisture on dielectric response of oil/paper insulation systems

The oil/paper insulation system in a transformer degrades under various chemical, thermal and electromechanical stresses during its operation. Dielectric response measurements like the Return Voltage Measurement (RVM) and Polarisation and Depolarisation Current (PDC) measurement are currently being used for condition assessment of the insulation. In the current research project, the ageing cond...

متن کامل

Aging Study of Oil Impregnated Repulped and Standard Cellulose through Measuring Viscometric Degree of Polymerization

This paper describes the aging behavior of the oil impregnated repulped cellulose and compares it with the aging behavior of the oil impregnated standard cellulose. In order to evaluate the reliability of using repulped cellulose in transformers, the accelerated aging process was applied to both types of cellulose by increasing the temperature to 150 °C and their aging behavior was studied and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: AIP Advances

سال: 2023

ISSN: ['2158-3226']

DOI: https://doi.org/10.1063/5.0143717