Temperature accuracy and temperature gradients in solution-state NMR spectrometers
نویسندگان
چکیده
منابع مشابه
Temperature accuracy and temperature gradients in solution-state NMR spectrometers.
In solution-state NMR spectrometers, there is a systematic deviation between the temperature of the sample and the temperature reported by the spectrometer. In addition, temperature gradients are often present in the sample. The size of both the temperature deviations and the temperature gradients depends on several factors, including the temperature, the flow rate of the heating/cooling gas, a...
متن کاملTemperature Gradients Induced Phase Separation in a Miscible Polymer Solution.
Jiro Kumaki,1 Takeji Hashimoto,1,2 and Steve Granick3 1Hashimoto Polymer Phasing Project, ERATO, JRDC, Keihanna Plaza, Seika, Kyoto 619-02, Japan 2Division of Polymer Chemistry, Graduate School of Engineering, Kyoto University, Kyoto 606-01, Japan 3Department of Materials Science and Engineering, University of Illinois, Urbana, Illinois 61801 (Received 27 February 1996) Phase separation occurre...
متن کاملEffect of solution saturation state and temperature on diopside dissolution
Steady-state dissolution rates of diopside are measured as a function of solution saturation state using a titanium flow-through reactor at pH 7.5 and temperature ranging from 125 to 175 degrees C. Diopside dissolved stoichiometrically under all experimental conditions and rates were not dependent on sample history. At each temperature, rates continuously decreased by two orders of magnitude as...
متن کاملTemperature dependence mitigation in stationary Fourier-transform on-chip spectrometers.
We present two techniques for mitigating the effects of temperature drifts in waveguide spatial heterodyne Fourier-transform on-chip spectrometers. In high-resolution devices, large optical path length differences result in an increased sensitivity to temperature variations and impose stringent requirements on the thermal stabilization system. In order to overcome this limitation, here we exper...
متن کاملTemperature gradients in the rabbit eye.
Measurements of the temperature of the various parts of the rabbit eye under both local and general Nembutal anesthesia were made ivith the thermistor as the temperature-measuring device at a room temperature of 22 to 24° C, and a relative humidity of 33 to 53 per cent. The equipment and its calibration are described in detail. The existence of a temperature difference of 6° C. (corrected for t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Magnetic Resonance
سال: 2002
ISSN: 1090-7807
DOI: 10.1016/s1090-7807(02)00120-9