Techniques for quantifying gaseous HOCl using atmospheric pressure ionization mass spectrometry

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct analysis of volatile methylsiloxanes in gaseous matrixes using atmospheric pressure chemical ionization-tandem mass spectrometry.

Atmospheric pressure chemical ionization-tandem mass spectrometry (APCI-MS/MS) was applied for the first time to the direct analysis of octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in gaseous matrixes without extraction or prior chromatographic separation. Mass spectrometric characteristics of both compounds under APCI conditions and their fragmentation behavior in MS...

متن کامل

Quantifying protein-fatty acid interactions using electrospray ionization mass spectrometry.

The application of the direct electrospray ionization mass spectrometry (ESI-MS) assay to quantify interactions between bovine β-lactoglobulin (Lg) and a series of fatty acids (FA), CH(3)(CH(2))(x)COOH, where x=6 (caprylic acid, CpA), 8 (capric acid, CA), 10 (lauric acid, LA), 12 (myristic acid, MA), 14 (palmitic acid, PA) and 16 (stearic acid, SA), is described. Control ESI-MS binding measurem...

متن کامل

Quantifying labile protein-ligand interactions using electrospray ionization mass spectrometry.

A new electrospray ionization mass spectrometry (ES-MS) approach for quantifying protein-ligand complexes that are prone to in-source (gas-phase) dissociation is described. The method, referred to here as the reference ligand ES-MS method, is based on the direct ES-MS assay and competitive ligand binding. A reference ligand (L(ref)), which binds specifically to the protein (P), at the same bind...

متن کامل

Characterizing electrospray ionization using atmospheric pressure ion mobility spectrometry.

Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmosp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Chemistry Chemical Physics

سال: 1999

ISSN: 1463-9076,1463-9084

DOI: 10.1039/a907362k