Technical Note: Testing an improved index for analysing storm discharge–concentration hysteresis
نویسندگان
چکیده
منابع مشابه
Technical Note: Testing an improved index for analysing storm discharge–concentration hysteresis
Analysis of hydrochemical behaviour during storm events can provide new insights into the process controls on nutrient transport in catchments. The examination of storm behaviours using hysteresis analysis has increased in recent years, partly due to the increased availability of high temporal resolution data sets for discharge and water quality parameters. A number of these analyses involve th...
متن کاملField Programmable Gate Array–based Implementation of an Improved Algorithm for Objects Distance Measurement (TECHNICAL NOTE)
In this work, the design of a low-cost, field programmable gate array (FPGA)-based digital hardware platform that implements image processing algorithms for real-time distance measurement is presented. Using embedded development kit (EDK) tools from Xilinx, the system is developed on a spartan3 / xc3s400, one of the common and low cost field programmable gate arrays from the Xilinx Spartan fami...
متن کاملTechnical Note : Why Is Vibration an Issue for Dissolution Testing ?
INTRODUCTION It has become apparent, in the recent past, that vibration within the tablet dissolution testing environment is a real issue. Although this may not have been too apparent in normal routine dissolution testing, the real impact of vibration has become a focal point as a result of the Prednisone “Calibrator Tablet” tests, which generally have to be performed every six months on each i...
متن کاملTechnical note : Molecular Index counting adjustment methods
BD Precise assays are fast, high-throughput, next-generation sequencing (NGS) library preparation kits tailored for small quantity RNA samples, such as single cells, using patented BDTM Molecular Indexing (MI) technology with Sample Index (SI) to label individual mRNA transcripts. During reverse transcription, the BD Precise assays apply a non-depleting pool of 6,561 MI barcodes (or 65,536 barc...
متن کاملTechnical Note: An Improved Range Chart for Normal and Long-Tailed Symmetrical Distributions
The distribution of the range of a sample, even in the case of a normal distribution, is not symmetric. Shewhart’s control chart for range and other approximations for range from skewed distributions and long-tailed (leptokurtic) symmetrical distributions assume the distribution of range as symmetric and provide ±3 sigma control limits. We provide accurate approximations for the R-chart control...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Hydrology and Earth System Sciences
سال: 2016
ISSN: 1607-7938
DOI: 10.5194/hess-20-625-2016