Technical Note: Investigating interplay effects in pencil beam scanning proton therapy with a 4D XCAT phantom within the RayStation treatment planning system
نویسندگان
چکیده
منابع مشابه
A comparison of two pencil beam scanning treatment planning systems for proton therapy
OBJECTIVE Analytical dose calculation algorithms for Eclipse and Raystation treatment planning systems (TPS), as well as a Raystation Monte Carlo model are compared to corresponding measured point doses. METHOD The TPS were modeled with the same beam data acquired during commissioning. Thirty-five typical plans were made with each planning system, 31 without range shifter and four with a 5 cm...
متن کاملBeam‐specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors
The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering...
متن کاملA benchmarking method to evaluate the accuracy of a commercial proton monte carlo pencil beam scanning treatment planning system
AcurosPT is a Monte Carlo algorithm in the Eclipse 13.7 treatment planning system, which is designed to provide rapid and accurate dose calculations for proton therapy. Computational run-time in minimized by simplifying or eliminating less significant physics processes. In this article, the accuracy of AcurosPT was benchmarked against both measurement and an independent MC calculation, TOPAS. S...
متن کاملRobust Planning for a Patient Treated in Decubitus Position with Proton Pencil Beam Scanning Radiotherapy
A challenging case was reported for a patient treated in decubitus position with proton pencil beam scanning. A regular robust plan with the consideration of the uncertainties of translational alignment and range accuracy cannot ensure the target coverage as revealed in two verification computed tomography (CT) scans during the first week of the treatment. The irreproducibility of daily alignme...
متن کاملEvaluation of the range shifter model for proton pencil‐beam scanning for the Eclipse v.11 treatment planning system
Existing proton therapy pencil-beam scanning (PBS) systems have limitations on the minimum range to which a patient can be treated. This limitation arises from practical considerations, such as beam current intensity, layer spacing, and delivery time. The range shifter (RS) - a slab of stopping material inserted between the nozzle and the patient - is used to reduce the residual range of the in...