Technical note: Infusion, sampling, and vacuum-assisted collection devices for use in ruminally cannulated calves

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vacuum-assisted wound closure (VAC) with simultaneous bone transport in the leg: a technical note.

Successful treatment of infected non union in long bone fractures has always been a challenge. Segmental excision followed by bone transport is one of the common modalities of treatment in such difficult cases. The soft tissue coverage of the resulting wounds was however not well described in the literature. The authors would like to report a simple technique that was used. After segmental bone...

متن کامل

Technical note: Evolution of exit velocity in suckling Brahman calves.

The purpose of this study was to assess changes in exit velocity (EV) of Brahman calves from 21 d of age (DOA) to 56 d postweaning (231.30 ± 1.23 DOA). Spring-born calves (n = 308) from 2006 to 2008 were sired by 18 bulls. Exit velocity (m/s) was determined as the rate of speed of a calf traversing 1.83 m after being released from a working chute. Temperament score was determined as the average...

متن کامل

Technical Note on Vacuum Assisted Closure-Basket Fixation of Scrotal Skin Grafts

641 With great interest, we have read the publication “The Vacuum Assisted Closure (VAC)-Basket for Easy Fixation of Scrotal Skin Grafts” by Huettinger et al. [1]. The authors describe their experience with a self-constructed vacuum-assisted closure basket for fixation of splitthickness skin grafts in the urogenital area for defect coverage after Fournier’s gangrene. We would like to congratula...

متن کامل

Endoscopic-Assisted Ommaya Reservoir Placement: Technical Note

Ommaya reservoir placement has been an option for patients requiring cerebrospinal fluid (CSF) access since the 1960s. It is preferred to repeat lumbar punctures, both in terms of patient comfort and the consistency of intrathecal drug concentration. Technological developments have advanced the placement technique, allowing for better accuracy and reduced complications. Freehand placement was f...

متن کامل

Technical Note: Stress-Induced Birefringence in Vacuum Systems

Even scientific grade optical glasses show birefringence when small external forces are applied to the sample. Stress-induced birefringence can be particularly detrimental to the state of polarization of light when a laser beam is transmitted through the glass. This is especially the case for glass windows of a vacuum chamber. Since compensation of spatially inhomogeneous birefringence is extre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Dairy Science

سال: 2018

ISSN: 0022-0302

DOI: 10.3168/jds.2018-14651