Technical Assessment of Frozen Soil on Geothermal Heat Pump Technology in Western Canada
نویسندگان
چکیده
This study examines the thermal performance of a two-dimensional borehole system, featuring U-shaped pipe embedded in porous soil, through application computational fluid dynamics. The investigation encompasses 24 cases, assessing impact various factors such as soil conductivity (k = 1.5, 1.84, 2 W/mK), average temperature (T 280-285 K), and moisture content (10%-55%) on ice formation heat transfer enhancement. k-ε turbulence model Darcy-Forchheimer are employed for medium, respectively. Furthermore, solidification is utilized to monitor potential within system. findings reveal that an increase enhances between while simultaneously reducing formation. Additionally, higher levels lead elevated outlet decreased soil. Lastly, it observed becomes negligible when reaches 285 K.
منابع مشابه
Assessment of Hybrid Geothermal Heat Pump Systems - Technology Installation Review
No portion of this publication may be altered in any form without prior written consent from the U.S. Department of Energy and the authoring national laboratory. both residential and commercial/institutional buildings. However, GHPs often have higher first costs than conventional systems making short-term economics unattractive. This disadvantage can be magnified in commercial buildings, many o...
متن کاملScaling in Geothermal Heat Pump Systems
INTRODUCTION Water quality is a frequently overlooked issue in the application of geothermal heat pump (GHP) systems. When considered at all, is often viewed as a problem unique to open loop systems. In residential open loop applications water is supplied directly to the heat pump’s refrigerant-to-water heat exchanger. If the water has a tendency to be scale forming, fouling of the heat exchang...
متن کاملNational Deployment of Domestic Geothermal Heat Pump Technology: Observations on the UK Experience 1995–2013
Uptake of geothermal heat pump technology in the UK and corresponding development of a domestic installation industry has progressed significantly in the last decade. This paper summarizes the growth process and reviews the research that has been specifically concerned with conditions in the UK. We discuss the driving forces behind these developments and some of the supporting policy initiative...
متن کاملLiterature Review on the Calculation of Vertical Ground Heat Exchangers for Geothermal Heat Pump Systems
The calculation of Ground Heat Exchanger (GHE) performance is very important for predicting the performance and estimating the initial cost of geothermal heat pump systems. In North America it is estimated that on average GHE are oversized by about 10% ~ 30%. A vertical Ground Heat Exchanger (VGHE) is most common because of its smaller environmental influence and land field requirement. This pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2023
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202339604007