TCTAP C-139 When Stent is Dislodged
نویسندگان
چکیده
منابع مشابه
Extraction of a Fully Deployed Coronary Stent during Retrieval of Another Dislodged Stent
Coronary stent dislodgement is a rare and serious complication of percutaneous coronary intervention and is associated with major adverse cardiac events. Successful retrieval of the stent is recommended in this situation because it is important for the prognosis. Recently, a patient was referred to our hospital with a dislodged coronary stent. When attempting to percutaneously extract the dislo...
متن کاملEsophageal metalic stent migration. Case report of a dislodged stent retrieval.
BACKGROUND Metallic stent placing is the first choice in the treatment of malign or benign strictures of the esophagus. Stent migration is a well-known complication of this procedure. We report a case of stent migration in which surgical laparoscopic intervention was used to retrieve it. METHODS An 85 years old man with unsuccessfully endoscopic retrieval of a migrated stent underwent laparos...
متن کاملWhen every $P$-flat ideal is flat
In this paper, we study the class of rings in which every $P$-flat ideal is flat and which will be called $PFF$-rings. In particular, Von Neumann regular rings, hereditary rings, semi-hereditary ring, PID and arithmetical rings are examples of $PFF$-rings. In the context domain, this notion coincide with Pr"{u}fer domain. We provide necessary and sufficient conditions for...
متن کاملWhen is an ectopically placed ureteral stent acceptable?
*E-mail: [email protected] We report a rare case of an ectopically placed ureteral stent, which was acceptable and functional. obstructing 8 × 15-mm proximal right-sided ureteral calculus. There were also multiple nonobstructing renal calculi on the left side. An antegrade ureteral stent was placed to relieve his infected and obstructed right kidney. During stent placement, the interventional ra...
متن کاملRetrieval of dislodged coronary stent from left renal artery by gooseneck snare☆
A rapamycin-eluting stent was dislodged during attempt of implantation at the proximal right coronary artery, which was found by fluoroscopy to have migrated into the anterior trunk of the left renal artery. We chose a 5 mm diameter Amplatz gooseneck snare and successfully retrieved the lost stent from the lodging vessel.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2019
ISSN: 0735-1097
DOI: 10.1016/j.jacc.2019.03.332