TCTAP C-099 Coronary Thrombosis During Complex PCI Using Step by Step Retrograde Approach for LAD#7 CTO
نویسندگان
چکیده
منابع مشابه
The retrograde technique for recanalization of chronic total occlusions: a step-by-step approach.
Chronic total occlusion recanalization still represents the final frontier in percutaneous coronary intervention. Retrograde chronic total occlusion recanalization has recently become an essential complement to the classical antegrade approach. In experienced hands, the retrograde technique currently has a high success rate with a low complication profile, despite frequent utilization in the mo...
متن کاملA step by step approach
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584 Step 1: developing the study question . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584 Defining the study question . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
متن کامل[Successful recanalisation of RCA CTO using retrograde approach].
A 51-year-old female two years after CABG presented with unstable angina and inferior wall ischaemia. Coronary angiography revealed occluded graft to RCA and chronic total occlusion of RCA with good collateral flow from distal LAD to RCA. The CTO was successfully crossed and dilated through epicardial collaterals from distal LAD (retrograde approach). Finally, antegrade angioplasty with two ste...
متن کاملAdaptive Line Enhancement Using a Parallel IIR Filter with A Step-By-step Algorithm
A step-by-step algorithm for enhancement of periodic signals that are highly corrupted by additive uncorrelated white gausian noise is proposed. In each adaptation step a new parallel second-order section is added to the previous filters. Every section has only one adjustable parameter, i.e., the center frequency of the self-tuning filter. The bandwidth and the convergence factor of each secti...
متن کاملDesign of Microstructure Response Using a Complex Step Plasticity Approach
Microstructure-sensitive design is performed using a newly developed Multiscale Complex Step Method. Algorithmic implementation of the complex-step method is based on conventional multiscale Taylor or FE2 direct model, with the difference being that the microstructural deformation gradient is modeled as a complex number with a small imaginary component. We introduce methods to calculate derivat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2016
ISSN: 0735-1097
DOI: 10.1016/j.jacc.2016.03.305