TCTAP C-057 Transradial Bifurcation Angioplasty Using Bioresorbable Vascular Scaffold and Kissing Balloon Technique
نویسندگان
چکیده
منابع مشابه
Absorb Bioresorbable Vascular Scaffold in Complex Coronary Bifurcation Interventions
Treatment of coronary bifurcation lesions is common in everyday practice and accounts for ≤20% of all percutaneous coronary interventions. The treatment of these lesions with drug-eluting stents, especially when a double-stent technique is used, remains challenging and is associated with a lower procedural success and a higher rate of long-term adverse cardiac events such as stent restenosis an...
متن کاملBioresorbable Vascular Scaffold Korean Expert Panel Report
Bioresorbable vascular scaffold (BRS) is an innovative device that provides structural support and drug release to prevent early recoil or restenosis, and then degrades into nontoxic compounds to avoid late complications related with metallic drug-eluting stents (DESs). BRS has several putative advantages. However, recent randomized trials and registry studies raised clinical concerns about the...
متن کاملDelayed disruption of a bioresorbable vascular scaffold.
(A) Pre-procedural angiogram demonstrating a focal lesion at left circum previously implanted in the ostial left anterior descending artery (LAD). implantation of a 3.5 12.0 mm bioresorbable vascular scaffold (BVS) 3.5-mm noncompliant balloon. (C) The 6-month follow-up angiogram sh follow-up angiogram after gentle pre-dilation with a 2.0-mm balloon per order to obtain optical coherence tomograp...
متن کاملStent-supported reconstruction of the aortoiliac bifurcation with the kissing balloon technique.
BACKGROUND Bilateral iliac artery obstructions involving the aortic bifurcation or high-grade stenosis of the abdominal aorta are not usually considered an indication for percutaneous treatment. The purpose of the present study was to evaluate the initial and long-term results of primary stent implantation for reconstruction of the aortic bifurcation. METHODS AND RESULTS In 48 patients with o...
متن کاملCutting balloon use may ease the optimal apposition of bioresorbable vascular scaffold in in-stent stenosis
Bioresorbable vascular scaffolds (BVS) have different mechanical properties as compared to metallic stents. Therefore, the standard procedural technique to achieve appropriate deployment may differ. Utilisation of debulking techniques, including cutting balloon and directional atherectomy prior to BVS deployment, is still questionable. Herein, we discuss a case of coronary in-stent restenosis a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2016
ISSN: 0735-1097
DOI: 10.1016/j.jacc.2016.03.262