TCT-631 A Robust Ex-vivo Functional Mitral Valve Model to Test Novel Transcatheter Mitral Valve Devices

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Mitral Valve Implantation

T he rationale for the development of a transcatheter mitral valve implantation (tMVI) procedure, either percutaneous or via minimally invasive surgery (MIS), arose from consideration of several key surgical concepts. First, mitral valve replacement is the most effective modality and the gold standard procedure for reliably reducing mitral regurgitation (MR). The efficacy and risks of mitral va...

متن کامل

Failed valve-in-valve transcatheter mitral valve implantation.

A 73-year old man underwent trans-septal anterograde implantation of a 26-mm Sapien-XT valve (Edwards Lifesciences, CA, USA) to treat a degenerated 27-mm Carpentier-Edwards bioprosthesis. During the follow-up, the patient experienced severe haemolysis with moderate-to-severe inter-valvular leak, and fluoroscopy revealed possible incomplete apposition of the Sapien-XT (Fig. 1). Reoperation was p...

متن کامل

Marcus-gunn phenomenon with- mitral valve prolapse

Marcus-gunn phenomenon is a congenital and sometimes hereditary anomaly, in which a ptotic eyelid retracts momentarily when the mouth is open, or the jaw is moved. These associated movements attributed to abnormal connections between the central mechanisms innervating the pterygoid and elevator muscles. Sometimes this anomaly is associated with dual,s retraction syndrome, duplex kindneys and ur...

متن کامل

Transcatheter Mitral Valve Replacement With a Novel Dual Stent Bioprosthesis.

There has been great interest in transcatheter mitral valve replacement (TMVR) as a potential therapy for high-risk patients with severe mitral regurgitation, with several distinct device systems undergoing first-in-man clinical studies. The Intrepid TMVR (Medtronic Inc, Redwood City, CA), designed for transapical delivery, comprises 2 interconnected self-expanding nitinol stents: (1) an inner ...

متن کامل

A novel approach to in vivo mitral valve stress analysis.

Three-dimensional (3-D) echocardiography allows the generation of anatomically correct and time-resolved geometric mitral valve (MV) models. However, as imaged in vivo, the MV assumes its systolic geometric configuration only when loaded. Customarily, finite element analysis (FEA) is used to predict material stress and strain fields rendered by applying a load on an initially unloaded model. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 2016

ISSN: 0735-1097

DOI: 10.1016/j.jacc.2016.09.773