TCT-584 Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent: 3 Year Follow-Up from the COMPARE II trial
نویسندگان
چکیده
منابع مشابه
The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.
INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compar...
متن کاملClinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 pat...
متن کاملThe three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
AIMS The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). METHODS AND RESULTS One thousand seven hundred and seven patients were randomised to unrestricted...
متن کاملDelamination of abluminal polymer of biolimus-eluting stent.
Manuscript received August 10, 2011; accepted September 3, 2011. Corporation, Tokyo, Japan) with abluminal biodegradable polymer in the mid-RCA was attempted. It passed through the everolimus-eluting stent in the proximal RCA without difficulty. However, it would not advance to the target lesion in the mid-RCA (Fig. 1C). Additional balloon inflation was performed. A 12-mm Driver Sprint stent (M...
متن کاملUltrathin Strut Biodegradable Polymer Sirolimus‐Eluting Stent Versus Durable‐Polymer Everolimus‐Eluting Stent for Percutaneous Coronary Revascularization: 2‐Year Results of the BIOSCIENCE Trial
BACKGROUND No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polyme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2014
ISSN: 0735-1097
DOI: 10.1016/j.jacc.2014.07.648