Tailored nanodiamonds for hyperpolarized C13 MRI
نویسندگان
چکیده
منابع مشابه
Hyperpolarized Xenon Brain MRI
Since hyperpolarized 129Xe MRI was first demonstrated in the lung, air space imaging using hyperpolarized noble gases (129Xe and 3He) has progressed at a rapid rate (Goodson, 2002; Zhou, 2011c). Owing to high lipid solubility, absence of background signal in biological tissue, non-invasiveness, lack of radioactivity, different relaxation to oxygenated and deoxygenated blood, and larger chemical...
متن کاملHyperpolarized xenon for NMR and MRI applications.
Nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) suffer from intrinsic low sensitivity because even strong external magnetic fields of ~10 T generate only a small detectable net-magnetization of the sample at room temperature (1). Hence, most NMR and MRI applications rely on the detection of molecules at relative high concentration (e.g., water for imaging of biological tissue) o...
متن کاملCardiovascular Applications of Hyperpolarized MRI
Many applications of MRI are limited by an inherently low sensitivity. Previous attempts to overcome this insensitivity have focused on the use of MRI systems with stronger magnetic fields. However, the gains that can be achieved in this way are relatively small and increasing the magnetic field invariably leads to greater technical challenges. More recently, the development of a range of techn...
متن کاملHyperpolarized Helium MRI of Asthma
A distinguishing feature of asthmatic lungs is that, when provoked, the airways constrict heterogeneously [1]. However, the tools typically used to study ventilation heterogeneity in humans, i.e., measurement of lung mechanics [2] and multiple-breath inert gas washout [3], provide only global and implicit assessment of the functional impact of structural changes. Since airways constitute the pa...
متن کاملHyperpolarized Kr MRI of lungs
Hyperpolarized (hp) Kr (spin I = 9/2) is a promising gas-phase contrast agent that displays sensitivity to the surface chemistry, surface-to-volume ratio, and surface temperature of the surrounding environment. This proof-of-principle study demonstrates the feasibility of ex vivo hp Kr magnetic resonance imaging (MRI) of lungs using natural abundance krypton gas (11.5% Kr) and excised, but othe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review B
سال: 2020
ISSN: 2469-9950,2469-9969
DOI: 10.1103/physrevb.101.155416