T1-insensitive flow suppression using quadruple inversion-recovery

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial T1 mapping at 3.0T using inversion recovery FLASH readout

Background Myocardial T1 mapping methods such as modified Look-Locker inversion-recovery (MOLLI) typically use balanced steady state free precession (bSSFP) readout, which is known to be particularly sensitive to off resonance and thus limits its utility at higher field strengths. Fast low angle shot (FLASH) imaging is known to be more robust against susceptibility artifacts than bSSFP. However...

متن کامل

Fast T1 Mapping using modified Double-Inversion Recovery pre-pulse

INTRODUCTION The rapid measurement of the longitudinal relaxation time (T1) would allow for dynamic quantification of tissue perfusion or therapy response after administration of an extracellular or target specific T1 lowering contrast agent. Currently used T1 mapping methods are based on Inversion Recovery (IR) approaches and the subsequent sampling of the recovery of the Mz magnetization [1]....

متن کامل

T1 mapping of myocardium using inversion recovery cine at 3.0T

Methods The sequence, IR-rttfl, performs realtime turboflash acquisition after an inversion pulse to capture the recovery of inverted magnetization. It is immune to T1 unrelated issues (e.g., field inhomogeneity). Diastolic images (about 12) are selected for T1 calculation using [4]. A trigger delay (about 300-400 ms) is applied before the inversion pulse so that initial magnetization recovery ...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Accelerated aortic plaque imaging using small field of view imaging and quadruple inversion recovery magnetization preparation

Introduction Autopsy data has demonstrated that the abdominal aorta offers a valuable early window for the study of atherosclerosis. Current MRI strategies often suffer from long scan times or require slice gaps. We sought to implement a small field-of-view approach (zoom imaging) (Buecker, A. et al, 1998), to allow complete coverage of the thoracic and abdominal aorta. To improve blood signal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2002

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.10292