Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring
نویسندگان
چکیده
منابع مشابه
Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring
Glaucoma is a common optic neuropathy that can lead to irreversible vision loss, and intraocular pressure (IOP) is the only known modifiable risk factor. The primary method of treating glaucoma involves lowering IOP using medications, laser and/or invasive surgery. Currently, we rely on in-office measurements of IOP to assess diurnal variation and to define successful management of disease. The...
متن کاملIntraocular pressure monitoring post intravitreal steroids: a systematic review.
The use of intravitreal (IVT) corticosteroids for treatment of posterior segment diseases has increased significantly over the last decade. A commonly recognized complication of IVT steroids is secondary ocular hypertension (OHT) that can occur immediately secondary to direct intraocular volume increase or weeks to months later as a result of increased outflow resistance. We performed a meta-an...
متن کاملEfficacy of a Contact Lens Sensor for Monitoring 24-H Intraocular Pressure Related Patterns
PURPOSE To study performance of a contact lens sensor (CLS) for 24-hour monitoring of IOP-related short-term patterns and compare with IOP obtained by pneumatonometry. METHODS Prospective clinical trial. Thirty-one healthy volunteers and 2 glaucoma patients were housed for 24 hours in a sleep laboratory. One randomly selected eye was fitted with a CLS (Triggerfish, Sensimed, Switzerland), whi...
متن کاملNoninvasive intraocular pressure monitoring: current insights
Glaucoma is the second leading cause of blindness worldwide and intraocular pressure (IOP) is currently its only modifiable risk factor. Peak IOP has for a long time been considered as a major contributor to glaucoma progression, but its effects may depend not only on its magnitude, but also on its time course. The IOP is nowadays considered to be a dynamic parameter with a circadian rhythm and...
متن کاملComparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use.
OBJECTIVE(S) We compared a convenient, cuffless, wrist-type ambulatory blood pressure monitoring (ABPM) device (BPro) and a standard arm-type ABPM monitor under ambulatory conditions. METHODS Fifty normotensive and prehypertensive volunteers who had no interarm differences in BP were enrolled. The wrist and arm monitors were attached to the left wrist and the right arm, respectively, and prov...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Therapy
سال: 2016
ISSN: 0741-238X,1865-8652
DOI: 10.1007/s12325-016-0388-4