Systematic Error in Gas Chromatography-Mass Spectrometry–Based Quantification of Hydrolyzed Urinary Steroids

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic error in gas chromatography-mass spectrometry-based quantification of hydrolyzed urinary steroids.

Gas chromatography-mass spectrometry-based metabolite profiling can lead to an understanding of various disease mechanisms as well as to identifying new diagnostic biomarkers by comparing the metabolites related in quantification. However, the unexpected transformation of urinary steroids during enzymatic hydrolysis with Helix pomatia could result in an underestimation or overestimation of thei...

متن کامل

Identification and quantification of neutral fecal steroids by gas-liquid chromatography and mass spectrometry: studies

The excretion of fecal neutral steroids was studied in six normocholesterolemic subjects and one hypercholesterolemic subject fed a standardized diet supplemented with butter fat or corn oil. The neutral steroids in the diets and in feces were identified by gas-liquid chromatography combined with mass spectrometric analyses of the chromatographic effluents. The three main sterols in the diets w...

متن کامل

Method for screening urinary steroids by gas chromatography.

Numerous methods are available for measuring urinary steroids in evaluating endocrine dysfunctions. Measurements of these particular steroids, or groups of them, usually involve tedious isolation methods, corrections for interferences and losses of the steroid, and (or) expensive reagents. We show how gas-liquid chromatography provides a rapid, sensitive, and direct method for several steroid m...

متن کامل

Gas chromatography tandem mass spectrometry offers advantages for urinary steroids analysis

Gas chromatography mass spectrometry has been the lynchpin of clinical assessment of steroid profiles for ∼3 decades. The improvements in assay performance offered by tandem mass spectrometry were assessed. Across the spectrum of glucocorticoid and androgen analytes tested, limits of detection and quantitation were ∼20 fold lower with triple than single quadrupole systems, but the more noticeab...

متن کامل

Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methods are needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry (GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which are clinically relevant androgens ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cancer Epidemiology Biomarkers & Prevention

سال: 2010

ISSN: 1055-9965,1538-7755

DOI: 10.1158/1055-9965.epi-09-0581