System-Level Tests of Transformer Differential Protection Using an IEC 61850 Process Bus

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dependability Optimization of Process-level Protection in an IEC-61850-Based Substation

Power substations are intensively renovated toward using information and communication technologies such as object oriented modeling and Ethernet networks. In the last two decades, Substation automation systems used capabilities of network communication services adopted from sophisticated international standardizations such as IEC 61850. Distributed safety related functions take advantage of th...

متن کامل

Demonstration of Adaptive Overcurrent Protection Using Iec 61850 Communications

This paper contains a description of an adaptive protection scheme that has been implemented and demonstrated in a hardware in the loop simulation environment using commercially available protection hardware and IEC 61850 communications. The implementation is based on an actual 11kV system which includes distributed generation and network automation. IEC 61850 communications offers several bene...

متن کامل

1 Performance Evaluation of IEC 61850 Process

The paper presents the performance of a novel distributed bus differential protection scheme, which utilizes independent multi-principle advanced protection algorithms, including differential percent slope, delta phase directional comparison, rate of change of differential (ROCOD) currents, delta phase directional comparison on neutral current differential, and a check zone to secure the electr...

متن کامل

Impact of IEC 61850-9-2 Standard-Based Process Bus on the Operating Performance of Protection IEDS: Comparative Study

IEC 61850-9-2 is an international substation automation standard that proposes a Process Bus communication network between process level equipment and bay level Intelligent Electronic Devices (IEDs) used for power systems protection and control. This paper considers the drive towards the use of IEC 61850-9-2 Process Bus in substations. The impact of the IEC 61850-9-2 standard on the operating p...

متن کامل

Evaluation of Process to Bay Level Networking Delay in IEC 61850 Substation Communication System

The modern and high-speed Peer-to-Peer IEC 61850 has opened the chance for planning and developing the sampled values that are supported information exchange among IEDs. Over the method bus network, it’s important to comprehend the transmission responsibility and real-time performance of SVs and GOOSE messages for all-digital IEC 61850 station automation systems (SASs) protection applications t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 2014

ISSN: 0885-8977,1937-4208

DOI: 10.1109/tpwrd.2013.2291789