Syringe contamination by propofol: a possible mechanism
نویسندگان
چکیده
منابع مشابه
Syringe plunger contamination by hazardous drugs: a comparative study.
AIM The purpose of this study was to perform a comparative cyclophosphamide contamination level test with Becton Dickinson® syringe plungers with Phaseal® Closed System Transfer Devices and Equashield® syringe plungers under routine oncological compounding conditions. METHOD The ChemoGlo™ sampling kit and analysis services were used to test for cyclophosphamide contamination levels on the syr...
متن کاملComparative Study of Syringe Contamination by Hazardous Drugs
Aim e purpose of this study was to compare surface contamination resulting from standard syringe plungers and cylinders compared to using the EQUASHIELD® Syringe Unit. Method e contamination level of standard syringes was compared to that of EQUASHIELD® Syringe Units, after repeated pharmaceutical manipulations using an antineoplastic (Cyclophosphamide) drug. Results Signi cant levels of up to ...
متن کاملPossible pathogenic mechanism of propofol infusion syndrome involves coenzyme q.
BACKGROUND Propofol is a short-acting intravenous anesthetic agent. In rare conditions, a life-threatening complication known as propofol infusion syndrome can occur. The pathophysiologic mechanism is still unknown. Some studies suggested that propofol acts as uncoupling agent, others suggested that it inhibits complex I or complex IV, or causes increased oxidation of cytochrome c and cytochrom...
متن کاملSyringe contamination following intramuscular and subcutaneous injections.
FOR many years it had been customary to give a series of intravenous injections of a drug such as neoarsphenamine with the same syringe, merely rinsing the syringe with antiseptic and distilled water before passing on to the next patient. Largely as a result of investigation of cases of postarsphenamine jaundice it has become recognized in recent years that a syringe which has been used for an ...
متن کاملPropofol emulsion and bacterial contamination.
Package insert information provided with propofol advises prompt administration following its drawing-up. This study has examined the delays which occur between drawing-up and administration of propofol in clinical practice and the incidence of bacterial contamination occurring under such conditions. Two hundred and fifty-four clinical uses of propofol were examined. Mean elapsed times (range) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anesthesia/Journal canadien d'anesthésie
سال: 2001
ISSN: 0832-610X,1496-8975
DOI: 10.1007/bf03016212