Chiral imaging of collagen by second-harmonic generation circular dichroism
We provide evidence that the chirality of collagen can give rise to strong second-harmonic generation circular dichroism (SHG-CD) responses in nonlinear microscopy. Although chirality is an intrinsic structural property of collagen, most of the previous studies ignore that property. We demonstrate chiral imaging of individual collagen fibers by using a laser scanning microscope and type-I colla...
متن کاملEnantiomeric Separation and Circular Dichroism Detection of Metalaxyl Acid Metabolite by Chiral High Performance Liquid Chromatography
The enantiomers of metalaxyl acid metabolite (MX-acid) were separated by HPLC using cellulose-tris-(3,5-dimethylphenyl-carbamate) (CDMPC) as chiral stationary phase. The effects of mobile phase composition, flow rate and column temperature on the resolution were investigated and good separation was achieved with n-hexane/2-propanol/trifluoroacetic acid as mobile phase. The circular dichroisms d...
متن کاملEnantiomeric Excess Sensitivity to Below One Percent by Using Femtosecond Photoelectron Circular Dichroism.
Photoelectron circular dichroism (PECD) is experimentally investigated with chiral specimens with varying amounts of enantiomeric excess (ee). As a prototype, we measure and analyze the photoelectron angular distribution from randomly oriented fenchone molecules in the gas phase that result from ionization with circularly polarized femtosecond laser pulses. The quantification of these measureme...
متن کاملCircular dichroism nano-imaging of two-dimensional chiral metal nanostructures.
Here we report on a nanoscale circular dichroism (CD) imaging for a two-dimensional chiral pair of nanostructures to elucidate the relationship between nanoscale chirality and CD activity. The chiral pair exhibited local ellipticity as high as 42 degrees in the CD signal at the center, with signals of both handedness coexisting in one nanostructure.
متن کاملWell Plate Circular Dichroism Reader for the Rapid Determination of Enantiomeric Excess.
Circular dichroism (CD) spectropolarimeters typically employ one photoelastic modulator. However, spectropolarimeters employing two or even four modulators are more versatile and can be used to subvert common measurement errors arising from imperfectly isotropic samples or sample holders. Small linear anisotropies that can cause large errors in CD measurement can be associated with multi-well s...