Synchrotron radiation response characterization of coplanar grid CZT detectors
نویسندگان
چکیده
منابع مشابه
Stability and Characteristics of Large CZT Coplanar Electrode Detectors
The single polarity charge sensing method based on coplanar grid electrodes has demonstrated promising results on CZT detectors having volumes of ~1 cm. This paper presents the performance of two coplanar grid CZT detectors having dimensions of 1.5 1 5 1.0 cm2, among the largest CZT spectrometers that have been reported. Energy resolutions of 2.3% and 2.0% full-width half-maximum were obtained ...
متن کاملAn Investigation on Cooling of CZT Co-Planar Grid Detectors
The effect of moderate cooling on CdZnTe semiconductor detectors has been studied for the COBRA experiment. Improvements in energy resolution and low energy threshold were observed and quantified as a function of temperature. Leakage currents are found to contribute typically ∼5 keV to the widths of photopeaks.
متن کاملCoplanar grid CdZnTe detectors for space science applications
The characteristics and performance for two of the latest coplanar grid CdZnTe detectors, which use the thirdgeneration coplanar grid design, will be discussed. These detectors, with dimensions of 1.5×1.5×0.9 cm and 1.5×1.5×0.95 cm, were fabricated by Baltic Scientific Instruments, Ltd., using crystals from Yinnel Tech, Inc. The high μeτe product measured for these crystals will lead to improve...
متن کاملCZT imaging detectors for ProtoEXIST
We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...
متن کاملAdvanced Readout ASICs for Multielement CZT Detectors
A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise pream...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 2005
ISSN: 0018-9499
DOI: 10.1109/tns.2005.856759