Synchrotron Radiation Excited Semiconductor Processes.
نویسندگان
چکیده
منابع مشابه
Synchrotron Radiation/lasers and Doubly-excited Atoms
This report highlights a series of joint theoretical and experimental collaborations which started over ten years ago in Taiwan. The recent topic program Synchrotron Radiation and Multiply-excited Atoms, sponsored by the National Center for Theoretical Sciences (NCTS) at Tsinghua University in Hsinchu and organized by K. T. Chung and C. S. Hsu, o®ers an excellent opportunity for many of us to w...
متن کاملMeasurement of synchrotron-radiation-excited Kossel patterns.
Kossel line patterns contain information on the crystalline structure, such as the magnitude and the phase of Bragg reflections. For technical reasons, most of these patterns are obtained using electron beam excitation, which leads to surface sensitivity that limits the spatial extent of the structural information. To obtain the atomic structure in bulk volumes, X-rays should be used as the exc...
متن کاملSynchrotron Radiation and Pretzeled Orbits Geometry of Synchrotron Radiation Illumination
Turning on a `pretzel' , or any closed orbit distortion, can substantially alter the path of synchrotron radiation (SR), in some instances causing it to strike components not designed to absorb the radiation. In this paper I develop equations useful in determining the source position and angle of dipole SR as a function of the pretzel amplitude and angle. Formula for linear power deposition and...
متن کاملElectroweak Synchrotron Radiation*
We calculate the emission rate and spectrum for radiation of neutral electroweak bosons (Z”) f rom an electron in a weak external homogeneous electromagnetic field satisfying 1 f Fcly Fp”/1/2 < Fc 3 mzc3/eti. The calculational method is based on the source theory formulation of quantum field theory introduced by Schwinger. In particular for ultra-relativistic electrons, we find that the 2’ emis...
متن کاملIntramyocardial vascular volume distribution studied by synchrotron radiation-excited X-ray fluorescence.
We evaluated the vascular volume distribution with fine resolution (0.1-1.3 mg myocardial tissue) in the sagittal plane of the left ventricle by using the microsphere filling method in 21 dogs. The coronary arterial volume density in the sagittal plane did not exhibit normal distribution and was characterized by variability among the outer-to-inner layers and within the layers (+2SD/-2SD > 80 t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Review of Laser Engineering
سال: 1991
ISSN: 0387-0200,1349-6603
DOI: 10.2184/lsj.19.11_1082