Synchronous Waveform Measurements to Locate Transient Events and Incipient Faults in Power Distribution Networks
نویسندگان
چکیده
A new method is proposed to identify the location of transient events, including incipient faults, in power distribution systems, by using synchronized measurements from an emerging class sensors, called waveform measurement units (WMUs). WMUs capture voltage and current waveforms time domain. The consists three steps. first step characterize oscillatory modes components all captured WMUs, conducting a multi-signal modal analysis. second construct circuit model for underlying feeder at identified dominant mode(s) event. final event with means that involves certain forward backward analyses constructed model. requires installing as few only two WMUs. It can also utilize several when are available. performance assessed on IEEE 33-bus test system; different cases such sub-cycle multi-cycle permanent well benign yet informative events capacitor bank switching. Both accuracy robustness verified. analysis results this paper provide insights possible applications WMU measurements; while they address highly challenging problem networks.
منابع مشابه
fault location in power distribution networks using matching algorithm
چکیده رساله/پایان نامه : تاکنون روشهای متعددی در ارتباط با مکان یابی خطا در شبکه انتقال ارائه شده است. استفاده مستقیم از این روشها در شبکه توزیع به دلایلی همچون وجود انشعابهای متعدد، غیر یکنواختی فیدرها (خطوط کابلی، خطوط هوایی، سطح مقطع متفاوت انشعاب ها و تنه اصلی فیدر)، نامتعادلی (عدم جابجا شدگی خطوط، بارهای تکفاز و سه فاز)، ثابت نبودن بار و اندازه گیری مقادیر ولتاژ و جریان فقط در ابتدای...
Power Transformer Incipient Faults Monitoring
Power transformers are important and expensive components in the electric power system. The knowledge of the actual status of the transformer insulation behavior, load tap changer performance, temperature, and load condition is necessary in order to evaluate the service performance concerning reliability, availability and safety. Systems abnormalities, loading, switching and ambient condition n...
متن کاملRemote Monitoring of Incipient Faults Using Gprs in Power Transformers
− One of the most applied procedures for detention of incipient faults in power transformers, such as partial discharges, electrical arcing and overheating, is the analysis of the concentration of gases dissolved in the isolating mineral oil. This analysis usually is carried through in a laboratory through chromatography in gaseous phase. Although it presents trustworthy results the chromatogra...
متن کاملActive Distribution Networks Restoration after Extreme Events
After extreme events such as floods, thunderstorms, blizzards and hurricanes there will be devastating effects in the distribution networks which may cause a partial or complete blackout. Then, the major concern for the system operators is to restore the maximum critical loads as soon as possible by available generation units. In order to solve this problem, this paper provides a restoration s...
متن کاملAgreement in synchronous networks with ubiquitous faults
In this paper we are interested in synchronous distributed systems subject to transient and ubiquitous failures. This includes systems where failures will occur on any communication link, systems where every processor will experience at one time or another send or receive failure, etc., and, following a failure, normal functioning resuming after a finite time. Notice that these cases cannot be ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Smart Grid
سال: 2021
ISSN: ['1949-3053', '1949-3061']
DOI: https://doi.org/10.1109/tsg.2021.3081017