Synchronised TeraHertz Radiation and Soft X-rays Produced in a FEL Oscillator

نویسندگان

چکیده

We present a scheme to generate synchronised THz and soft X-ray radiation pulses by using free-electron laser oscillator driven high repetition rate (of order 10–100 MHz) energy recovery linac. The backward in the cavity interacts with successive electron bunch, thus producing few 105 soft/hard photons per shot (namely 1012–1013 photons/s) via Thomson/Compton back-scattering, mJ-class pulse within temporal jitter of beams accelerated superconducting cavities linac (less than 100 fs). Detailed simulations have been performed assess capability for typical wavelengths interest, between 10 50 μm TeraHertz 0.5–3 nm X-rays.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft X-rays and Extreme Ultraviolet Radiation: Principles and.

1.1 (a) Confirm that for a photon energy h ω, with corresponding wavelength λ in vacuum, the two are related by eV nm 1239.842 ⋅ = ⋅ λ ω h Values for physical constants are given in Appendix A, page 419. (b) What wavelength in nm corresponds to photons of energy 543.1 eV? (c) What wavelengths in vacuum are associated with the K and L-absorption edges of neon, chlorine, cobalt, and ruthenium? 1....

متن کامل

Progress toward a Soft X-ray Fel

The recent successes in operating FELs from the far infrared to the visible and near UV [1], together with a better understanding of the physics and technology of these systems, are leading us to explore again the possibility of using FELs to produce coherent radiation in the XUV region, at wavelength shorter than 100 nm . In this paper we derive a set of scaling laws, which we will use to stud...

متن کامل

Comparison between a FEL amplifier and oscillator

Previous experiments with the Raman FEL, situated at the Twente University, showed that the output was influenced by the rather strong increase of the current density with time . The field emission diode has been modified to produce a more constant current pulse to simplify the analysis of the measurements . This resulted in a lower current density of the electron beam . With this new diode two...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2022

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app12168341