Susceptibility‐induced distortion correction in hyperpolarized echo planar imaging
نویسندگان
چکیده
منابع مشابه
Susceptibility‐induced distortion correction in hyperpolarized echo planar imaging
PURPOSE Echo planar imaging is an attractive rapid imaging readout that can image hyperpolarized compounds in vivo. By alternating the sign of the phase encoding gradient waveform, spatial offsets arising from uncertain frequency shifts can be determined. We show here that blip-reversed echo planar imaging can also be used to correct for susceptibility and B0 inhomogeneity effects that would ot...
متن کاملOptimized distortion correction technique for echo planar imaging.
A new phase-shifted EPI pulse sequence is described that encodes EPI phase errors due to all off-resonance factors, including B(o) field inhomogeneity, eddy current effects, and gradient waveform imperfections. Combined with the previously proposed multichannel modulation postprocessing algorithm (Chen and Wyrwicz, MRM 1999;41:1206-1213), the encoded phase error information can be used to effec...
متن کاملGeometric distortion correction in echo volumar imaging
Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...
متن کاملCorrection of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach.
OBJECTIVE This study investigates the application of a modified reversed gradient algorithm to the Propeller-EPI imaging method (periodically rotated overlapping parallel lines with enhanced reconstruction based on echo-planar imaging readout) for corrections of geometric distortions due to the EPI readout. MATERIALS AND METHODS Propeller-EPI acquisition was executed with 360-degree rotationa...
متن کاملA referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐13C]pyruvate and [1‐13C]lactate
Single-shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized 13 C-labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2017
ISSN: 0740-3194,1522-2594
DOI: 10.1002/mrm.26839