Enumeration of Legionella pneumophila in cooling tower water systems.

Legionella pneumophila, the causative agent of Legionnaires' disease, is known to colonise and frequently grow in cooling tower waters. Disease is acquired by inhaling aerosol contaminated by legionellae. Determination of the count of Legionella pneumophila in cooling tower waters may, therefore, be useful for risk assessment. In our survey, 103 water samples from 50 cooling towers were examine...

متن کامل

Negative enrichment procedure for isolation of Legionella pneumophila from seeded cooling tower water.

A negative enrichment procedure was developed which was capable of isolating Legionella pneumophila directly from seeded air-conditioning cooling tower water onto laboratory media. This procedure was based on an 8-h incubation under conditions that were bactericidal to the indigenous water microflora but merely bacteriostatic to L. pneumophila.

متن کامل

Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC) at 36 °C was performed from June to Octob...

متن کامل

Improved facility and sensitivity in the use of guinea pigs for the isolation of Legionella pneumophila from cooling tower water.

The established criteria for the determination of the optimum time for the sacrifice of guinea pigs inoculated with samples of cooling tower water were found to be inadequate for the detection of low levels of Legionella pneumophila. By ignoring the requirement for fever and by sequentially sacrificing the infected guinea pigs on days 3 through 5 postinoculation, we simplified the procedure, an...

متن کامل

Dynamics of Legionella spp. and bacterial populations during the proliferation of L. pneumophila in a cooling tower facility.

The dynamics of Legionella spp. and of dominant bacteria were investigated in water from a cooling tower plant over a 9-month period which included several weeks when Legionella pneumophila proliferated. The structural diversity of both the bacteria and the Legionella spp. was monitored by a fingerprint technique, single-strand conformation polymorphism, and Legionella spp. and L. pneumophila w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied and Environmental Microbiology

سال: 1983

ISSN: 0099-2240,1098-5336

DOI: 10.1128/aem.45.4.1254-1260.1983