منابع مشابه
Mitigation of Corrosion on Magnesium Alloy by Predesigned Surface Corrosion
Rapid corrosion of magnesium alloys is undesirable in structural and biomedical applications and a general way to control corrosion is to form a surface barrier layer isolating the bulk materials from the external environment. Herein, based on the insights gained from the anticorrosion behavior of corrosion products, a special way to mitigate aqueous corrosion is described. The concept is based...
متن کاملHeat Treatment Of Cobalt-Base Alloy Surgical Implants With Hydroxyapatite-Bioglass For Surface Bioactivation
ASTM F-75 Cobalt-base alloy castings are widely used for manufacturing orthopedic implants. This alloy needs both homogenization and solutionizing heat treatment after casting, as well as bioactivation of the surface to increase the ability of tissue bonding. In this study, ASTM F-75 Cobalt-base substrate was heat treated at 1220°C for 1 hour in contact with Hydroxyapatite-Bioglass powder in or...
متن کاملCorrosion and Surface Treatment of Magnesium Alloys
The need for fuel efficiency and increased performance in transportation systems continually places new demands on the materials used. The design criteria which automobile and aerospace industries are primarily concerned with are density, strength, stiffness, and corrosion resistance. Low-density materials may reduce fuel costs, increase range, and allow larger payloads. High strength and stiff...
متن کاملSurface characterization and cytocompatibility evaluation of silanized magnesium alloy AZ91 for biomedical applications.
Mg alloys with high Al contents have superior corrosion resistance in aqueous environments, but poor cytocompatibility compared to that of pure Mg. We have silanized the cast AZ91 alloy to improve its cytocompatibility using five different silanes: ethyltriethoxysilane (S1), 3-aminopropyltriethoxysilane (S2), 3-isocyanatopyltriethoxysilane (S3), phenyltriethoxysilane (S4) and octadecyltriethoxy...
متن کاملBioresorbable Drug-Eluting Magnesium-Alloy Scaffold for Treatment of Coronary Artery Disease
The introduction of metallic drug-eluting stents has reduced the risk of restenosis and widened the indications of percutaneous coronary intervention in treatment of coronary artery disease. However, this medical device can induce hypersensitive reaction that interferes with the endothelialization and healing process resulting in late persistent or acquired malapposition of the permanent metall...