Surface Ionization Detector for Gas Chromatography:Characteristics and Applications to Organic Substances.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A surface ionization detector for capillary gas chromatography.

A novel surface ionization detector using a reducing quartz liner and a Mo emitter with a quartz enclosed internal heater for selective measurement of alkylamines by gas chromatography is designed and evaluated.

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Phase Frequency Detector Using Transmission Gates for High Speed Applications

In this paper a new phase-frequency detector is proposed using transmission gates which can detect phase difference less than 500ps. In other word, the proposed Phase-frequency Detector (PFD) can work in frequencies higher than 1.7 GHz, whereas a conventional PFD operates at frequencies less than 1.1 GHz. This new architecture is designed in TSMC 0.13um CMOS Technology. Also, the proposed PFD a...

متن کامل

The feasibility of using microstrip gas detector as radon detector for earthquake prediction

In the last decade, several studies have concluded that elevated concentrations of radon gas in soil or groundwater could be the sign of an imminent earthquake. It is believed that in case of sudden movement of rocks before earthquake, radon is released from the depth of ground and reached the surface. In this way, by measuring Radon concentration change, earthquake prediction is possible. In t...

متن کامل

Calorimetric Ionization Detector

A new mode of operation for ionization detectors is described. The amount of ionization produced in a detector is detennined by measuring the amount of heat generated during the carrier collection process. Very high detection sensitivities, including single carrier detection, may be achieved at cryogenic temperatures. Results from an experimental device operated at T=O.3K is presented.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 1991

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.7.415