Surface EMG signal normalisation and filtering improves sensitivity of equine gait analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface EMG Signal Amplification and Filtering

Electromyographic (EMG) signals have been widely employed as a control signal in rehabilitation and a means of diagnosis in health care. Signal amplification and filtering is the first step in surface EMG signal processing and application systems. The characteristics of the amplifiers and filters determine the quality of EMG signals. Up until now, searching for better amplification and filterin...

متن کامل

Analysis of surface EMG signal morphology in Parkinson's disease.

A novel approach is presented for the analysis of surface electromyogram (EMG) morphology in Parkinson's disease (PD). The method is based on histogram and crossing rate (CR) analysis of the EMG signal. In the method, histograms and CR values are used as high-dimensional feature vectors. The dimensionality of them is then reduced using the Karhunen-Loève transform (KLT). Finally, the discrimina...

متن کامل

Using EMG Signal Analysis

A signal analysis technique is developed for discriminating a set of lower arm and wrist functions using surface EMG signals. Data wete obtained from four electrodes placed around the proximal forearm. The functions analyzed included wrist flexion/extension, wrist abduction/adduction, and forearm pronation/supination. Multivariate autoregression models were derived for each function; discrimina...

متن کامل

Filtering the surface EMG signal: Movement artifact and baseline noise contamination.

The surface electromyographic (sEMG) signal that originates in the muscle is inevitably contaminated by various noise signals or artifacts that originate at the skin-electrode interface, in the electronics that amplifies the signals, and in external sources. Modern technology is substantially immune to some of these noises, but not to the baseline noise and the movement artifact noise. These no...

متن کامل

Reliability of normalisation methods for EMG analysis of neck muscles.

Acceptable reliability of normalisation contractions in electromyography (EMG) is paramount for testing conducted over a number of days or if normal laboratory strength testing equipment is unavailable. This study examined the reliability of maximal voluntary isometric contractions (MVIC) and sub-maximal (60%) isometric contractions for use in neck muscle EMG studies. Surface EMG was recorded b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Comparative Exercise Physiology

سال: 2019

ISSN: 1755-2540,1755-2559

DOI: 10.3920/cep190028